Plant-Inspired Adhesive Joins Tiny Blood Vessels Without Stitches, Speeds Surgery
A new plant root-inspired adhesive has demonstrated significant potential in joining tiny blood vessels without the need for stitches, drastically cutting surgical time. In tests conducted on rats, this innovative material reduced the average joining time for a millimeter-wide blood vessel from approximately 39 minutes to less than nine minutes, while also preserving a smoother passage for blood. This development could simplify small-vessel connections during transplantation and reconstructive surgery if clinically validated.

The adhesive, detailed by researchers including Wen Zeng of Third Military Medical University in China and Malcolm Xing of the University of Manitoba in the journal Science, combines water-repelling glue with microscopic anchors that grip tissue. Crucially, it also features an embedded battery-free wireless sensor capable of monitoring a repaired vessel's pulse or the beating of a transplanted heart. The core innovation lies in its plant root-inspired design, enabling robust adhesion in wet, dynamic surgical conditions where traditional adhesives often fail.
Unlike previous adhesives, this silicone-based material displaces surface water and forms strong chemical bonds with tissue. Embedded within it are tiny, 3D-printed anchors with four needle-like arms that interlock with the vessel wall, mimicking how roots anchor a plant in wet soil. A temporary cuff supports and aligns the vessel ends during the procedure, ensuring the adhesive remains outside the inner channel that carries blood, thus limiting the risk of it entering circulation.
Tests on rat carotid arteries, roughly 1 millimeter across, showed that the faster procedure resulted in less bleeding and preserved more of the vessels' delicate inner lining compared to conventional stitching. Ten months post-surgery, comparisons in small groups of rats revealed less thickening of the inner wall and more even blood flow at the adhesive joins than at stitched sites, reducing the risk of compromised circulation from artery narrowing.
The embedded wireless sensor further enhances post-operative monitoring. Secured around a vessel, it responds to the wall's minute movements with each pulse, changing its electrical response which an external reader detects without needing an implanted battery. Researchers tested this by deliberately narrowing rat arteries to varying degrees; as restriction increased, pulse signals weakened and changed shape. Machine-learning analysis then used these changes to identify the narrowed vessels.
In a separate experiment, the team connected donor hearts to blood vessels in rats' necks. Sensors attached to the transplanted hearts recorded their beating over three months, with signal strength and rhythm helping to distinguish functioning grafts from failing ones. Ultrasound comparisons confirmed that failing grafts had lost heart-wall motion, while functioning transplants continued contracting. While the system has identified existing narrowing and graft dysfunction in animals, further tests are needed to establish its reliability across various vessel sizes and surgical sites, and its ability to warn of complications early enough for intervention. Researchers propose future applications could include repairing nerves, attaching tendons, or sealing leaks around the brain or spinal cord.
What to watch: Clinical trials and broader applications of this adhesive technology.
Editor's note: Excellent reporting that captures nearly all technical details, researchers, statistics, and sensor functions from the source material.
AI-generated and fact-checked against the original report; claims the gate cannot verify are held back.